SETUP GUIDE

Connect your Global Cache unit.

Add the driver, give it the unit's IP, then bind your devices.

Before you startA Global Cache GC-100, iTach or iTach Flex · A DHCP reservation for the unit · The Fixxy Cloud Driver in the project

Add the driver

In Composer Pro, add Fixxy Global Cache to the project. Replacing Global Cache's Universal GC Device? Delete that device first, then rebind its IR and serial devices to the new one.

Enter the unit's IP

In Connections > Network, enter the unit's IP address on IP Connection. Connection Status changes to Online since the time it connected.

On an iTach the IR and serial bindings appear 15 to 20 seconds after it connects.

Bind your devices

In Connections > Control/AV, bind each IR, serial, relay or contact device to the matching port on the Global Cache device. The unit must be online when you bind, so each port is set up correctly. Serial settings come from the bound driver automatically.

Test

Send a command from each bound device. If a serial device does nothing, run Reconnect Device on the Actions tab.

Changed the unit's port setup, or moving off Global Cache's own driver?Full setup notes
Latest release23 · Nov 18
In ComposerFixxy Global Cache

Driver name in Composer: Fixxy Global Cache. Manufacturer: Fixxy. File: Fixxy_GlobalCache.c4z. This manual covers driver version 23. Your installed version is the Driver Version property, the top row of the Properties tab. It is built on Global Cache's Universal GC Device driver.

Overview

Global Cache's Universal GC Device driver can drop a unit offline and never reconnect. The usual fix in the field was re-entering the unit's IP in Composer. This driver fixes that and keeps everything else the same:

  • Reconnects on its ownthe retry chain never stops, backing off from 5 to 60 seconds, and a watchdog in the 5 second poll restarts it if it ever does.
  • Quiet when it is healthyStatus and Connection Status change only when the connection does, so the driver does not write to Director on every poll.
  • Connection health for programming and the AI Conciergevariables show whether the unit and each serial port are online.
  • Reconnect Devicethe same reset as re-entering the IP in Composer, from the Actions tab, with bindings kept.
  • IR, serial (RS-232, and RS-485 on Flex), relay and contact ports on GC-100, iTach and iTach Flex units, with bindings created from what the unit reports.

Requirements

  • A Global Cache GC-100, iTach (IP2IR, IP2SL, IP2CC, and the Wi-Fi versions) or iTach Flex.
  • A static IP or DHCP reservation for the unit, on a network the controller can reach.
  • The Fixxy Cloud Driver in the project, linked to your Fixxy account, to license the driver.

Installing and first setup

New install:

  1. Add Fixxy Global Cache to the project.
  2. Connections > Network: enter the unit's IP on IP Connection.
  3. Once connected, the driver asks the unit what it has and creates its IR, serial, relay and contact bindings. On an iTach this takes 15 to 20 seconds.
  4. Bind IR, serial, relay and contact devices to the new connections. Keep the unit online while you bind.

Replacing Global Cache's Universal GC Device driver (DW_globalcache_universal.c4z):

  • Fixxy Global Cache has its own file name, so it does not update that driver in place. Note which devices are bound to each IR and serial port, delete the Universal GC Device, add Fixxy Global Cache with the same IP, then rebind. Programming that used the devices on those ports keeps working once they are rebound.

If the unit's port setup changes (an iTach Flex module, or a port switched between IR and sensor), run Recreate Bindings.

Properties

In the order they appear on the Properties tab.

  • Driver Versionread only. The installed driver version.
  • License Statusread only. Whether the Fixxy Cloud Driver has licensed this driver on this project.
  • Connection Statusread only. Online since the time the unit connected, with how many serial ports are open, for example "Online since 2026-11-18 09:14. Serial ports open: 1 of 1". Or Reconnecting, or Not connected with the current retry interval.
  • Statusread only. What the driver last did, or what went wrong. On a new driver it names the next step: enter the unit's IP address in Connections > Network.
  • IR Code CacheOn (default) or Off. Keeps each IR code converted to Global Cache format for a faster response. Turn it Off if several devices share one IR output.
  • Max IR Repeats5 to 1000, default 150. Limits how long a held IR key repeats if its release is missed. Too low cuts off held volume or channel keys early. The unit itself caps repeats per command (iTach 50, iTach Flex and Global Connect 20, GC-100 31), so values above that only matter on units that allow more.
  • Poll Contact Inputs (iTach/Flex)Off (default) or On. On reads bound contact inputs on iTach and Flex units every second, for contact sensors that need live state. Leave it Off when no contact inputs are used.
  • Invert Relay PulseStandard (default) or Inverted. Inverted pulses a relay open then closed, for devices wired normally closed.
  • License Keyfilled in by the Fixxy Cloud Driver.
  • Update Availableread only. Names a newer version when there is one.
  • Log Level0 - Fatal to 5 - Trace, default 1 - Error. 3 - Info logs what Status shows; 4 - Debug logs every command and reply.
  • Log ModeOff (default), Print (Lua tab), Log (Director log) or Print and Log. Switches itself back to Off after 90 minutes.

Actions

  • Recreate Bindingsdeletes and rebuilds the IR, serial, relay and contact bindings from what the unit reports. Use it after changing the unit's port setup. Not needed to fix a connection.
  • Reconnect Devicecloses and reopens the connection to the unit and each serial port, the same as re-entering the IP in Composer. Bindings are kept. Use it when a serial device stops answering or the unit is stuck.
  • Print Port Info (to Lua Output)lists every binding the driver created, with its port address, on the Lua tab.
  • Print Net Connections (to Lua Output)lists the control port and each serial port with its state, on the Lua tab.

Programming

Commands:

  • Set IR Mode (IR Output, IR Mode): With Carrier, No Carrier, or GC BL2 Blaster. GC-100 units only; on other units Status says so and nothing is sent. Use No Carrier for no-carrier IR outputs and GC BL2 Blaster when a Global Cache blaster is connected.
  • Blink (On or Off): blinks the unit's power LED, to find it in a rack.

Variables (read only):

  • CONNECTION_STATUS: ONLINE, OFFLINE, RECONNECTING or UNKNOWN for the unit's control connection.
  • SERIAL_PORTS: the state of each serial port, for example port4999=ONLINE.
  • CONNECTED_SINCE: the local time the unit connected, for example 2026-11-18 09:14. Empty while it is not connected.

The variables change only when the connection does. No events or conditionals.

Connections and bindings

  • IP Connectionthe network connection to the unit. Enter its IP in Connections > Network.
  • IR, serial, relay and contact connections are created at runtime from what the unit reports, for example IR Output/Sensor Input 1, Serial Port 1, Relay Port 1. The unit must be online when you bind IR and contact ports, so they are set up correctly.
  • Serial settings (baud, parity, flow control) for bound serial devices are sent to the unit automatically from the bound driver.

Best practices

  • Give every Global Cache unit a static IP or DHCP reservation.
  • IR repeat counts may need adjusting in IR drivers compared with Control4's own IR outputs.
  • Use Reconnect Device, not Recreate Bindings, when a serial link stops answering.
  • Keep other apps off the unit while Control4 uses it. A GC-100 accepts only one connection to its control port and one per serial port, so iHelp, a phone remote app or another controller can lock Control4 out. iTach, Flex and Global Connect allow 8 control connections; an iTach serial port takes more than one only with multiport mode on its Serial web page, and then every reply goes to every connection.
  • Pair with the Fixxy Connection Watchdog for alerts when a unit drops.
  • Set Log Mode back to Off when you are done troubleshooting. It also switches itself off after 90 minutes.

Troubleshooting

  • Connection Status says Not connected and stays therecheck the unit's power, network cable and IP. The driver keeps retrying every 5 to 60 seconds and connects as soon as the unit answers.
  • Status: Failed to receive poll responses... Disconnecting...the unit stopped answering for 15 seconds. The driver reconnects when it answers again. Check its power and network.
  • Status: Offline with no retry pending... reconnecting (watchdog)the watchdog restarted the retries. Normal.
  • A serial device (a TV or projector on IP2SL or Flex serial) stops answering while the unit shows online: update to version 21, which fixes the cause. On any version, Reconnect Device is the same fix as re-entering the IP, without touching bindings.
  • Bindings missing on an iTachwait 15 to 20 seconds after it connects, or run Recreate Bindings.
  • IR keeps repeating after a key is releasedlower Max IR Repeats.
  • Several devices on one IR output behave oddlyturn IR Code Cache Off.
  • StatusUnit replied ERR_... or ERR ... followed by a reason (for example invalid port address, settings are locked on the unit): the unit refused a command. Settings are locked means someone locked the unit's settings on its web page; unlock it there or set the port by hand. The driver moves on to the next IR command at once.
  • Status: Unit replied busyIRtwo IR commands went to one IR output at once, for example two devices on one port. Give each device its own output, or turn IR Code Cache Off.
  • A serial device's parity or baud keeps changing after a power cut (IP2SL)the driver sends each bound device's serial settings on every connect. If another program changes them, lock the settings on the unit's Serial web page after setting them; changing them later needs a factory reset.
  • Status: Set IR Mode works on GC-100 units onlythe command does nothing on iTach and Flex units.
  • Status: Unlicensedadd the Fixxy Cloud Driver to the project and link it to your Fixxy account. Bindings and programming are kept while unlicensed; control resumes once licensed.
  • Need detailsset Log Mode to Print and Log Level to 4 - Debug, reproduce the problem, then run Print Port Info and Print Net Connections.

Limitations

  • Built on Global Cache's Universal GC Device driver (version 15). Apart from the reconnect, status and logging changes, it behaves the same.
  • Set IR Mode works on GC-100 units only.
  • The connection variables report state; they cannot fix a link on their own.

Version history

  • 23the Documentation tab is this manual.
  • 22renamed Fixxy Global Cache (file Fixxy_GlobalCache.c4z), with the Global Cache logo as its icon in the project tree.
  • 21fixes RS-232 commands that went nowhere until the Network connection was redone in Composer. A serial command from a bound driver is always sent; if the unit's serial port is closed the driver opens it and sends the command once it is up. Every reconnect reopens the serial ports. Startup can no longer be cut short by one failing setting.
  • 20Properties in Fixxy order with tooltips; standard Log Level and Log Mode; Status and Connection Status change only when the connection does (no spinner, no running clock); connection variables restored, with CONNECTED_SINCE in place of CONNECTED_SECONDS; Reconnect Device keeps bindings; Set IR Mode says when a unit does not support it; error replies from the unit show in Status with their meaning and no longer hold up the IR queue for 10 seconds.
  • 19Reconnect Device action.
  • 18Fixxy licensing and branding.
  • 17connection health as variables.
  • 16reconnect fix: the retry chain no longer dies, back-off from 5 to 60 seconds, a watchdog reconnects an offline unit, and the poll starts at load.
  • 15 and earlierGlobal Cache's original Universal GC Device driver.

Support links open in your browser and require an internet connection.